EMPower Power Meters Model 7002-002 & -004

ETS-Lindgren's EMPowerTM Power Meters make fast, accurate power measurements, even at low power levels.
ETS-Lindgren's EMPower Power Meters make fast, accurate power measurements, even at low power levels. The EMPower modular plug-in card occupies one slot in the EMCenter, and includes four USB ports, accommodating any combination of up to four EMPower or EMPower Pulse sensors. Alternatively, an EMPower sensor can be connected directly to a PC using a standard USB port and included software.
Both power meters have an accuracy of 0.25 dB, making them suitable for measurements in accordance to automotive, military, telecom, and basic EMC standards.
EMPower is fully supported by TILE!, EMQuest, and other test automation software packages. Please contact ETS-Lindgren for additional information.
- Fast Performance: Up to 1 Million Samples per Second Measured Continuous Wave
- Accurate Measurements with Dynamic Range of:
- 65 dB for 6 GHz Model (Model 7002-002)
- 55 dB for 18 GHz Model (Model 7002-004)
- Low Measurement Uncertainty
Fast Performance
The EMPower Meters perform power measurements at a maximum sampling speed of 10 million samples per second.Accurate Measurements
EMPower allows high precision RF measurements with high dynamic range of 65 dB for the 6 GHz model, and 55 dB for the 18 GHz model.Low Measurement Uncertainty
Impedance mismatch is a main contributor to measurement uncertainty in RF power measurements. EMPower sensors have low VSWR to overcome this problem.Model | 7002-002 (Sensor) | 7002-004 (Sensor) |
Temperature Range (Use) | 0 C to +40 C (32 F to 104 F) | 0 C to +40 C (32 F to 104 F) |
Temperature Range (Storage) | -20 C to +85 C (4 F to 185 F) | -20 C to +85 C (4 F to 185 F) |
Relative Humidity | 10 to 90% (Non-condensing) | 10 to 90% (Non-condensing) |
Connector to Plug-in Card or PC (Data) | USB-B | USB-B |
USB Communication | USB 1.1 | USB 1.1 |
USB Power Consumption | < 200 mA | < 200 mA |
RF Input Connector | N-type Precision | N-type Precision |
Model | 7002-002 (Sensor) | 7002-004 (Sensor) |
Detector Type | Diode | Diode |
Measurement Function | RMS CW Power | RMS CW Power |
Calibrated Frequency Range | 9 kHz to 6 GHz | 80 MHz to 18 GHz |
Power Measuring Range | -55 dBm to +10 dBm | -45 dBm to +10 dBm |
Input Damage Level | >20 dBm | >20 dBm |
Resolution | 0.01 dB | 0.01 dB |
VSWR | <1.05 @ 10 MHz to 100 MHz <1.15 @ 100 MHz to 2 GHz <1.35 @ 2 GHz to 6 GHz | <1.20 @ 80 MHz to 10 GHz <1.35 @ 10 GHz to 18 GHz |
Maximum Linearity Error (0 dBm ref) | 0.05 dB/10 dB | 0.05 dB/10 dB |
Measuring Speed (Per Second) | 20K, 100K or 1 M | 20K, 100K or 1 M |
Accuracy (23 2 C) | 0.25 dB | 0.25 dB ( 10 GHz) 0.50 dB (> 10 GHz) |
Temperature Effect | < 0.15 dB Over Full Temperature Range | < 0.15 dB Over Full Temperature Range |
Measurement Units | dBm | dBm |